Event ID:
Source:
Server Administrator
Category:
Storage Service
Message:
Virtual disk degraded: Virtual Disk 1 (Virtual Disk 1) Controller 0 (PERC 5/i Integrated)


Event ID:
Source:
Server Administrator
Category:
Storage Service
Message:
Physical disk removed: Physical Disk 0:0:0 Controller 0, Connector 0


Event ID:
Source:
Server Administrator
Message:
Controller log file entry: VD 00/0 is now OPTIMAL: Virtual Disk 0 (Virtual Disk 0) Controller 0 (PERC 5/i Integrated)


Event ID:
Source:
Server Administrator
Message:
Redundancy lost: Virtual Disk 0 (Virtual Disk 0) Controller 0 (PERC 5/i Integrated)


Event ID:
Source:
Server Administrator
Message:
Device failed: Physical Disk 1:0:9 Controller 0, Connector 1


Event ID:
Source:
Server Administrator
Message:
Virtual disk degraded: Virtual Disk 0 (Virtual Disk 0) Controller 0 (PERC 5/i Integrated)


Event ID:
Source:
Server Administrator
Message:
Predictive Failure reported: Array Disk 0:4 Controller 0, Connector 0


Event ID:
Source:
Server Administrator
Category:
Instrumentation Service
Message:
Redundancy lost
Redundancy unit: System Board PS Redundancy
Chassis location: Main System Chassis
Previous redundancy state was: Normal


Event ID:
Source:
Server Administrator
Category:
Instrumentation Service
Message:
Log size is near or at capacity
Log type: ESM


Event ID:
Source:
Server Administrator
Category:
Storage Service
Message:
Controller event log: PD missing: SasAddr=0x5000c50001cde56d, ArrayRef=1, RowIndex=0x3, EnclPd=0xff, Slot=5.
: Controller 0 (PERC 5/i Integrated)


Event ID:
Source:
Server Administrator
Category:
Storage Service
Message:
Controller event log: PDs missing from configuration at boot: Controller 0 (PERC 5/i Integrated)


Event ID:
Source:
Server Administrator
Category:
Storage Service
Message:
Controller event log: VDs missing drives and will go offline at boot: 01: Controller 0 (PERC 5/i Integrated)


Event ID:
Source:
Server Administrator
Message:
Controller event log: VD 01/1 is now OFFLINE: Controller 0 (PERC 5/i Integrated)


Event ID:
Source:
Server Administrator
Category:
Storage Service
Message:
Controller event log: PD 04(e0/s4) is not a certified drive: Controller 0 (PERC 5/i Integrated)


Event ID:
Source:
Server Administrator
Category:
Storage Service
Message:
Controller event log: PD 04(e0/s4) is not a certified drive: Controller 0 (PERC 5/i Integrated)


Event ID:
Source:
Server Administrator
Category:
Instrumentation Service
Message:
Log size is full
Log type: ESM



Event ID:
Source:
Server Administrator
Category:
Storage Service
Message:
Controller log file entry: Physical Disk 1:0:4 Controller 0, Connector 1


Event ID:
Source:
Server Administrator
Category:
Storage Service
Message:
Unexpected sense. SCSI sense data: Sense key: 3 Sense code: 11 Sense qualifier: 0: Physical Disk 1:0:4 Controller 0, Connector 1


Event ID:
Source:
Server Administrator
Category:
Storage Service
Message:
The RAID controller firmware and driver validation was not performed. The configuration file is out of date or corrupted. C:\Program Files (x86)\Dell\SysMgt\sm\cfg\: Controller 0 (SAS 6/iR Integrated)


Event ID:
Source:
Server Administrator
Category:
Storage Service
Message:
The controller debug log file has been exported.: Controller 0 (PERC 5/i Integrated)


Event ID:
Source:
Server Administrator
Category:
Storage Service
Message:
The controller write policy has been changed to Write Through.


Event ID:
Source:
Server Administrator
Message:
Log size is no longer near or at capacity
Log type: ESM



Event ID:
Source:
Server Administrator
Category:
Storage Service
Message:
Controller battery is discharging: Battery 0 Controller 0


Found 23 records